Feb 02, 2026
Overview
The Ultra Series Downmixing Encoders UL-718AVP and UL-749AVP include a dedicated Dolby DSP processor for audio downmixing. This processor runs its own microcode, which must be updated separately from the main J+P firmware.
Keeping this microcode up to date improves debugging visibility and helps prevent intermittent audio dropouts.
The update is performed using a SyncMOS USB writer connected to the Encoder’s 4-pin Molex port.
Download
The download contains:
- SyncMOS SMAP Tool – Used to flash DSP microcode
- MCU_FW_V3.05.hex – Dolby DSP microcode file
- B2.0.6_TX.bin – Optional firmware required to activate the updated microcode
Required Hardware
- Windows PC (Windows 7 or newer; macOS not supported)
- SyncMOS MSM9066 USB writer with 5-pin to 4-pin Molex cable
- UL-718AVP or UL-749AVP Ultra Series Downmixing Encoder
Update Instructions
PART 1: Flash Dolby DSP Microcode
⚠️ Warning: Perform these steps in order. Skipping steps or changing default settings can damage the device.
-
Connect the SyncMOS USB writer to the Molex cable as shown below.
-
Connect the USB writer to the PC and the Molex connector to the Encoder’s 4-pin port.
- The UL-749AVP contains three Encoders. This process must be completed on all three.
-
Launch SMAP, select Writer MSM 9066, and update the writer firmware if prompted.
- Do not modify any default values.
- Select SM59R16A5L, 3V in the MCU section.
-
In the Code section:
- Set Initial Value to FF
- Enable Code
- Load MCU_FW_V3.05.hex
- In Configuration, set ISP Start Addr (N) to No ISP Code.
-
Set the following options:
- On-line ICP: Enabled
- Speed: Custom → 2
- Chip Erase: Enabled
- Blank Check: Disabled
- Program: Enabled
- Verify: Disabled
- Protect: Enabled
- MCU Reset: Enabled
- Power on the Encoder and wait for a solid Power LED.
- Click Autorun.
- Confirm the message Reset MCU finished!.
- Power-cycle the Encoder to complete Part 1.
PART 2: Update Firmware to Activate Microcode
⚠️ Important: Perform this section only after completing Part 1.
- If the system is below firmware B2.0.5, update all devices first. If already on B2.0.5, update only the Encoder to B2.0.6.
- Access the Encoder webUI.
- Select Update.
- Upload B2.0.6_TX.bin and allow the device to reboot.
- Confirm firmware version reads B2.0.6.
-
To verify microcode:
- Open the CLI from the webUI menu
- Send
VERSION_READ - Confirm response:
V3.05 2020-06-08
EZLogger
If audio issues persist after the update:
- Contact J+P Support to enable EZLogger.
- Provide the exact date/time of the issue along with your support ticket number.