Aug 04, 2020
- Overview
- Fix Through WebUI
Overview
Luxul firmware v4.2.0 has a new feature that prompts for a password change upon first login to the switch webUI.
This webUI behavior has no effect on running JADConfig to setup a Luxul switch with Just Add Power.
However, if JADConfig is run and then the webUI is opened, the wizard will demand a password change. This by itself is not bad. However, the driver to control switching must have an accurate username/password to function.
Fix Through WebUI
Option 1
Perform this Option to return the switch to the default username/password of admin/admin.
- Open the web interface of the Luxul switch
- In Password, set the new password to "Goodbye007"
- In IP Address, do not change any values.
- In Date & Time, set however you would like.
- In Information, System contact, System name, and System location must be left blank.
- Login to the switch with username/password of admin/Goodbye007
- Go to Configuration > Security > Switch > Users, click on the admin user, and change the password back to 'admin'
- Fin!
Option 2
Perform this Option to change the password on the switch and leave it at the new, more secure password.
- Open the web interface of the Luxul switch
- Set the new password to anything you want.
- Do not change the IP address, subnet mask, gateway, or DNS
- Set Date & Time and Information however you would like.
- Go to the control system driver for the Luxul switch and change the password to the new value.
- On the JADConfig Report file, change the password to the new value.
- Fin!